Action-kick sensitivity to D2 field errors at injection (R0 = 25 mm): Multipole |\Delta J/J\right| (10^{-3}) b_2/a_2 0.23 b_3/a_3 0.13 b_4/a_4 0.073 b_5/a_5 0.041 b_6/a_6 0.023 b_7/a_7 0.013 b_8/a_8 0.008 b_9/a_9 0.004 b_10/a_10 0.002 b_11/a_11 0.001 Note: 1. 1 unit multipole error on one D2 dipole 2. nominal injection; 11 sigma amplitude with zero crossing angle