tune meter recipe (January 21 06)(ahrens): single time tune measurement start from StartUp/ AgsTuneMeter the gui that appears is where you should stay (for now). Kick Voltage:controls voltage for both hori and vert PFN and kicks. Set by Vert kicker Voltage:(kV) box (right side high up). really is in Volts not kV, can set to 1000 up to 10000. Probably ok to go higher, not above 20000 for sure. time of kick/measurement: set by Trigger(us) (central column of page). From ags T0. The scope triggers earlier than the kickers by the amount set in the Delay(us) box, just below the trigger box in the central column. Which kicker will fire? Next Acquisition H kick Trig on/off and V Kick Trig on/of buttons again in the central column. You can ask for many acquisitions also with Num Acq button. No reason to do this at this point - no averaging going on yet. Don't mess with the Hori Kicker Timing and Vert Kicker Timing buttons at the top, i.e. don't turn them on. If you do, the kickers will stay on until you turn them off. You are overriding the programs take a shot control. Pet pages for the DAQ scope and the kickers are available on menu bar under setup. Be careful if you go there. If the scope is dead, some instructions are in the Haixin's web ags polarized area - in the ags tune meter write up. Most of that writeup is for the future.